02 149 5555 ถึง 60

 

ผู้วิจัย/Authors: orawan silpakit, paritat silpakit, somsri kittipongpisarn, rosukon chomcheun

ชื่อเรื่อง/Title: The diagnostic accuracy of the Thai version of brief community screening instrument for dementia (CSI-D).

แหล่งที่มา/Source: Journal of Mental Health of Thailand, Vol 25, No 1, January 2017, Page 32-46.

รายละเอียด / Details:

Objectives: To validate the CSI-D Thai version in the clinical setting against other screening tests such as IQCODE, clock drawing test and standard neuropsychological tests i.e, ADAS-COG, Trail Making Test ™ among Thai dementia patients.
Materials and Methods: There were 3 steps of study namely, first, to translate CSI-D into Thai. Secondly, neuropsychological tests such as Boston Thai naming card (BT), word list (WL) were prepared and then clinical evaluations and neuropsychological bettery tests were conducted at Srithanya and suanprung Hospital during October 2012-February 2015. Descriptive statistical analysis was used. The receiver operating analysis curve (ROC) was applied to comoare the area under curves (AUC) and the cut-off scores of each test were calculated.
Results: there were 147 cases divided into 54 control, 33 early dementia, 37 mild dementia and 23 moderate to severe dementia cases. The AUCs of CSI-D among these cases range from 0.59-0.83. The cut-off score was >-7 with a fair validity (sense=59.6, spec=68.5). The other tests such as ADAS-COG, BT, WL, TM were in details.
Conclusion: The CSI-D was validated in dementia patients at the psychiatric hospital and the accuracy was comparable to other screening tests. However, the new screening tool for each level such as primary, secondary level should be further developed.

Keywords: auc, csi-d, dementia, screening

ปีที่เผยแพร่/Year: 2017

Address: Srithanya Hospital, Suanpung Hospital

Code: 2017000086

ISSN/ISBN: 0859-497X

Country of publication: Thailand

Language: English

Category: Abstract